Description
- The Windows version includes easy-to-follow installation videos and system verification tests to ensure optimum performance and reliability. How-to videos provide on-screen instruction on instrument operation.
- The patented twin-tube design negates free-space errors introduced by thermal gradient variations or by initial mis-measurement of free space
- Permits low surface area measurements without requiring krypton by essentially eliminating free-space error, the limiting factor in typical static volumetric systems.
- Accelerates delivery of the analysis gas because sample uptake controls the rate at which the gas is delivered to the sample. This results in a surface area analyzer that is as fast as the physics of adsorption allows
- The use of a servo valve to control the rate of gas flow into the sample tube assures accurate attainment of target pressures without pressure overshoot
- Three choices of software control: embedded software with a keypad enabling the Gemini VII to be operated without an external PC, Windows XP or Vista operating system, or the Gemini VII confirm™ 21 CFR Part 11 option.
Advantages
- Low Cost
- System verification tests
- Fully automatic operation
- High throughput – up to four Geminis can be operated with single computer
- Capable of measuring low surface area materials
- Keypad- or computer-operated with Windows-driven software
- Choice of analysis mode (scan or equilibrate)
- No pressure overshoot
- Common mode rejection of free-space error effects
- No thermal-diffusion errors
- Optional stainless-steel Dewars
- 21 CFR Part 11 software option
- IQ/OQ Validation service (optional)
Three Model Options:
Gemini VII 2390a
Ideal for rapid and accurate surface area determinations by single-point and multipoint BET and Langmuir methods. In addition, provides standard methods for total pore volume, micropore analysis by the t-method, and much more. Included is the capability to determine statistical thickness surface area (STSA) of carbon blacks. (Refer to ASTM D 6556, ASTM D 3765, ISO/DIS 18852.2, or ISO/CD 4652-2/3.)
Gemini VII 2390p
Provides additional precision with the addition of a saturation pressure (P0) tube that allows the system to monitor the saturation pressure of the adsorptive on a continuous basis during an analysis. This design feature permits a rapid measurement of the adsorption isotherm to near-saturation, as well as determination of pore size distribution.
Gemini VII 2390t
Has all the ability of the 2390p, including a P0 tube, with the addition of a larger Dewar and longer sample tubes for extended analyses. This provides the additional capability to measure the total adsorption-desorption process. With this data set, one can perform a BJH or Dollimore-Heal pore size distribution using up to 1000 data points.